AA-7050D Atomic Absorption Spectrophotometer

The AA-7050D employs a double-beam total reflection optical system, automatically performing zero return, scanning, lamp positioning, mirror adjustment, and energy balancing based on the element wavelength selected in the method. It is widely applicable in metallurgy, petrochemicals, geology, medicine, environmental protection, scientific research, agriculture (soil/fertilizer), disease control, food safety, materials science, and commodity inspection. Capable of analyzing over 70 elements, it plays a critical role in micro and trace elemental analysis.

Dual-beam total reflection optical system with real-time lamp drift correction, automatic baseline compensation, and flame emission function. 

Spectral bandwidth: Six automatic slit settings (0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm).

Wavelength accuracy: ±0.1 nm;  Wavelength repeatability: ≤0.05 nm. 

Resolution: Better than 0.1 nm.

8-lamp turret with full computer control for rapid positioning and automatic lamp selection. 

Background correction: Deuterium lamp and self-reversal methods.

Wide-range high-sensitivity photo-multiplier tube.

Baseline stability: Dynamic: ≤0.003 A/30 min; Static: ≤0.002 A/30 min.

Automatic preheating for next element lamp ;  Supports simultaneous operation of 2 lamps.

Flame analysis performance: Characteristic concentration: Cu < 0.02 μg/mL;  Detection limit: Cu < 0.003 μg/mL;  RSD: ≤0.45%.

Automatic peak search with zero-return, scanning, lamp/mirror alignment, and energy balancing based on selected element wavelength.


Product features

Look More

Dual-beam total reflection optical system with real-time lamp drift correction, automatic baseline compensation, and flame emission function. 

Spectral bandwidth: Six automatic slit settings (0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm).

Wavelength accuracy: ±0.1 nm;  Wavelength repeatability: ≤0.05 nm. 

Resolution: Better than 0.1 nm.

8-lamp turret with full computer control for rapid positioning and automatic lamp selection. 

Background correction: Deuterium lamp and self-reversal methods.

Wide-range high-sensitivity photo-multiplier tube.

Baseline stability: Dynamic: ≤0.003 A/30 min; Static: ≤0.002 A/30 min.

Automatic preheating for next element lamp ;  Supports simultaneous operation of 2 lamps.

Flame analysis performance: Characteristic concentration: Cu < 0.02 μg/mL;  Detection limit: Cu < 0.003 μg/mL;  RSD: ≤0.45%.

Automatic peak search with zero-return, scanning, lamp/mirror alignment, and energy balancing based on selected element wavelength.