ICP-TOF-MS 3800 Inductively Coupled Plasma Time of Flight Mass Spectrometer

The ICP-TOF-MS 3800 can not only perform analysis on conventional liquid samples, but also be coupled with instruments such as laser ablation devices, electrothermal evaporation devices (graphite furnaces), and HPLC for sample analysis, greatly expanding its scope of use. The ICP-TOF-MS 3800 can simultaneously obtain complete information on all mass numbers within the detection range, truly achieving the same analysis time for a single mass number and all mass numbers. Regardless of the application, the analysis by the ICP-TOF-MS 3800 will be faster, more accurate, and more cost-effective than ever before!

3800.pngICP-TOF-MS 3800 Inductively Coupled Plasma Time of Flight Mass Spectrometer

Low operating costs Instrument operating costs are very important for each laboratory. The ICP-TOF-MS 3800 has a fast analysis speed and far lower argon consumption than the quadrupole ICP-MS. It takes only 25 seconds to analyze the 20 elements in the sample ICP-TOF-MS 3800.

The argon consumption of the ICP-TOF-MS 3800 is 12L/min, because the analysis speed of the ICP-TOF-MS3800 is more than 5 times faster than that of the quadrupole mass spectrometer, making it more than ten times lower than that of the quadrupole when analyzing each element, which of course saves a lot of costs.

The new octapole colliding cell (OCC) addresses the technical advantage of the ICP-TOF-MS 3800 that can simultaneously analyze all mass numbers. The mass-independent octapole colliding cell (OCC) can perform interference management in sample analysis and remove all interfering ions in the full mass range. The OCC is located inside the ICP-TOF-MS 3800 for easy maintenance and maintenance.

Rapid sample analysis ICP-TOF-MS 3800 has synchronous data collection capabilities. During the analysis process, all elements and their isotope information that ICP-MS can detect can be obtained for accurate quantitative analysis. All mass numbers are obtained at the same time, which means that users can see potential contaminants and elements that are not considered and concerned at this stage. This additional information can prompt users to investigate and quantify newly identified contaminants and elements. ICP-TOF-MS 3800‘s analysis speed is 5 times faster than any quadrupole ICP-MS. For users with a large number of samples, it is one of the must-have analysis tools!

Key Features

Look More

3800.pngICP-TOF-MS 3800 Inductively Coupled Plasma Time of Flight Mass Spectrometer

Low operating costs Instrument operating costs are very important for each laboratory. The ICP-TOF-MS 3800 has a fast analysis speed and far lower argon consumption than the quadrupole ICP-MS. It takes only 25 seconds to analyze the 20 elements in the sample ICP-TOF-MS 3800.

The argon consumption of the ICP-TOF-MS 3800 is 12L/min, because the analysis speed of the ICP-TOF-MS3800 is more than 5 times faster than that of the quadrupole mass spectrometer, making it more than ten times lower than that of the quadrupole when analyzing each element, which of course saves a lot of costs.

The new octapole colliding cell (OCC) addresses the technical advantage of the ICP-TOF-MS 3800 that can simultaneously analyze all mass numbers. The mass-independent octapole colliding cell (OCC) can perform interference management in sample analysis and remove all interfering ions in the full mass range. The OCC is located inside the ICP-TOF-MS 3800 for easy maintenance and maintenance.

Rapid sample analysis ICP-TOF-MS 3800 has synchronous data collection capabilities. During the analysis process, all elements and their isotope information that ICP-MS can detect can be obtained for accurate quantitative analysis. All mass numbers are obtained at the same time, which means that users can see potential contaminants and elements that are not considered and concerned at this stage. This additional information can prompt users to investigate and quantify newly identified contaminants and elements. ICP-TOF-MS 3800‘s analysis speed is 5 times faster than any quadrupole ICP-MS. For users with a large number of samples, it is one of the must-have analysis tools!